Mine Safety Appliances
Middle East
Select Region
Corporate Home
Africa
Asia Pacific
Europe
Latin America
Middle East
North America
MSA is the global leader in the development, manufacture and supply of sophisticated products that protect people's health and safety.
Customer Service
+ 971 2 633 3926


The Safety Company



Related Resources
Response Respirator Selector

MSA Fire Service Website

Regulatory Information

Repair Education - CARE

Warranty Information

Ask a Question

Have Someone Call Me

Image Library


Hip-Air™ Breathing Apparatus

HOME | MIDDLE EAST CATALOG | SUPPLIED AIR RESPIRATORS | AIRLINE RESPIRTORS | Hip-Air™ Breathing Apparatus

Printable Version of This Page
Email This Page

Enlarge Image





Principles of Operation
Operation of the Hip-Air Pressure Demand Breathing Apparatus is manual. It is an approved, rated five-minute escape device. The pressure demand air-line respirator phase is connected by an approved air-supply hose to a primary respirable air source; the worker breathes from this source with the valve of the egress (exit) cylinder of the device turned off until the user is ready to leave the working area. The user can leave, connected to the primary air source, or can open the egress cylinder valve and have approximately five minutes respiratory protection. When breathing from the air cylinder, the user can remain connected to the primary air supply and exit, or can disconnect from the air source for easier escape. If the primary air supply source should fail for any reason, the worker can switch to the egress cylinder by turning a valve and escape to a safe atmosphere.

Approvals & Standards
The Hip-Air Breathing Apparatus is approved by the National Institute for Occupational Safety and Health (NIOSH), Approval TC-13F-143 when the device is supplied with respirable air from either the small escape cylinder or from a primary compressed-air source; the approval requires that when connected to a primary air source, an air inlet pressure between 65 and 85 psig must be maintained through an approved hose length of between 8 and 300 feet. The approval requires that the compressed-air cylinder be fully charged with air conforming to at least Grade D of Compressed Gas Association Commodity Specification for Air, G-7-1; use limited to temperatures above -25 degrees F.

Applications
Chemical
Construction
Hazardous Materials
Nuclear
Oil and Gas
Welding

Hazards
Confined Space
Oxygen Deficiency
Toxic Atmosphere IDLH
Welding

Product Information
Provides respiratory protection for personnel who must work in atmospheres that are immediately dangerous to life and health (IDLH), such as in oil drilling and the manufacturing and handling of certain chemicals. Serves as both a long-duration work device and an escape device. Approved for respiratory protection for entry into, for extended periods of work in and for escape from IDLH atmospheres. If used for entry into IDLH atmospheres, the air-line must be connected before entry. The self-contained air supply is approved for escape only. Designed for good weight balance, the cylinder valve and pressure reducer are on the right side and the belt-mounted pressure demand regulator is positioned on the left side. The cylinder is connected to the regulator by a small length of neoprene air-supply hose, which rests on the wearers lower back, completely out of the way. One end of the hose attaches to the pressure regulator coming off the cylinder and the other to the top of a two-inlet manifold which leads directly to the regulator. The bottom inlet is equipped with a quick-disconnect device to attach the air-line to the unit, available with Snap-Tite, Foster, Hansen or Duff-Norton quick-disconnect. The cylinder valve is positioned on the front side of the cylinder so the wearer can simply tilt the cylinder and easily read the gauge. Also available is a Dual-Supply Hip-Air breathing apparatus. Dual-Supply increases mobility because workers do not need to remain tethered to a single air-supply hose throughout the work period. With dual-supply capability, users can connect from one pressurized continuous air source to another without losing continuity of airflow. When the first length of air-supply hose has reached its limit, the wearer simply plugs into a second approved air source and disconnects from the first. This technique is known as “leap-frogging” because it gives workers the ability to move from station to station without disrupting the supply of air.

Basic Info
Additional Product Information
  • Bulletin - Key Elements of a Sound Respiratory Protection Program (Bulletin No. 1000-61)
  • NIOSH approval matrix for Hip-Air/Comb. PD Airline Respirator (Approval Label Part No. 10002264)


Technical Information
  • Data Sheet - Hip-Air Breathing Apparatus (Data Sheet No. 01-03-12-MC)
  • Instruction and Maintenance Manual - Combination Breathing Apparatus (Part No. 477118)


Literature
How to Order From MSA Middle East:
Click Here to Locate a Distributor

Frequently Ordered Part Numbers:

10001696 COMB. PD APPARATUS,ULTRAVUE,MD,BLACK
10001697 COMB. PD APPARATUS,ULTRAVUE,MD,BLACK
485565 CYLINDER & VALVE ASSY,ESCAPE,5-MIN,3000
487150 RESPIRATOR ASSY,HIP-AIR,UV,COMP CYL,FOST
487151 RESPIRATOR ASSY,HIP-AIR,UV,COMP CYL,FOST
487153 APPARATUS-HIP,COMB.P.D.
487154 APPARATUS-HIP,COMB.P.D.
487155 RESPIRATOR ASSY,HIP-AIR,UV,COMP CYL,SNPT
487156 APPARATUS-HIP,COMB.P.D.
487157 APPARATUS-HIP,COMB.P.D.
487158 APPARATUS-HIP,COMB.P.D.
487166 RESPIRATOR ASSY,HIP-AIR,UV,COMP CYL,FOST
487167 RESPIRATOR ASSY,HIP-AIR,UV,COMP CYL,FOST
487169 APPARATUS-HIP,COMB.P.D.
487170 RESPIRATOR ASSY,HIP-AIR,UV,COMP CYL,SNPT
487171 APPARATUS-HIP,COMB.P.D.
487172 RESPIRATOR ASSY,HIP-AIR,UV,COMP CYL,HANS
487173 RESPIRATOR ASSY,HIP-AIR,UV,COMP CYL,HANS
488387 APPA,COM PD-HIP,COMP,CASE
811689 COMB.PD AP,HP,UE,MD,HY,BK
811695 COMB.PD AP,HP,UE,MD,HY,BK
811696 COMB.PD AP,HP,UE,MD,HY,BK
811698 COMB.PD AP,HP,UE,MD,HY,BK
811699 COMB.PD AP,HP,UE,MD,HY,BK
811750 COMB.PD AP,HP,UE,MD,HY,BK
811751 COMB.PD AP,HP,UE,MD,HY,BK
811752 RESPIRATOR ASSY,HIP-AIR,UE,COMP CYL,HANS
811753 COMB.PD AP,HP,UE,MD,HY,BK
811826 COMB.PD AP,HP,UE,MD,HY,BK
811832 RESPIRATOR ASSY,HIP-AIR,UE,COMP CYL,SNPT
811833 COMB.PD AP,HP,UE,MD,HY,BK
811835 COMB.PD AP,HP,UE,MD,HY,BK
811836 COMB.PD AP,HP,UE,MD,HY,BK
811837 COMB.PD AP,HP,UE,MD,HY,BK
811838 COMB.PD AP,HP,UE,MD,HY,BK
811839 COMB.PD AP,HY,UE,MD,HY,BK
811840 COMB.PD AP,HP,UE,MD,HY,BK
816699 RESP. ASSY,R95,ADV 200LS,SM
818159 CYLINDER & VALVE ASSY,2216 PSI,3AL,5-MIN
10001698 COMB. PD APPARATUS,ULTRAVUE,MD,BLACK
10001699 COMB. PD APPARATUS,ULTRAVUE,MD,BLACK
10001700 COMB. PD APPARATUS,ULTRAVUE,MD,BLACK
10001701 COMB. PD APPARATUS,ULTV. FCPC,MED,BLACK
10001702 COMB. PD APPARATUS,ULTRAVUE,MD,BLACK
10001703 COMB. PD APPARATUS,ULTRAVUE,MD,BLACK
10001750 RESPIRATOR ASSY,HIP-AIR,UE,3AL,FOSTER BR
10001751 RESPIRATOR ASSY,HIP-AIR,UE,3AL,FOSTER ST
10001752 COMB. PD APPARATUS,ULTR. ELT.,MED,BLACK
10001753 COMB. PD APPARATUS,ULTR. ELT.,MED,BLACK
10001754 COMB. PD APPARATUS,ULTR. ELT.,MED,BLACK
10001755 COMB. PD APPARATUS,ULTR. ELT.,MED,BLACK
10001756 COMB. PD APPARATUS,ULTR. ELT.,MED,BLACK
10001757 COMB. PD APPARATUS,ULTR. ELT.,MED,BLACK
10001758 RESPIRATOR ASSY,HIPAIR,FOSTER BR,W/3AL
10001759 RESPIRATOR ASSY,HIPAIR,FOSTER STL,W/3AL
10001760 COMB. PD APPARATUS,ULTRAVUE,MD,BLACK
10001761 COMB. PD APPARATUS,ULTRAVUE,MD,BLACK
10001762 COMB. PD APPARATUS,ULTRAVUE,MD,BLACK
10001763 RESPIRATOR ASSY,HIP-AIR,UV,3AL,HANSEN BR
10001764 RESPIRATOR ASSY,HIP-AIR,UV,3AL,HANSEN SS
10001765 RESPIRATOR ASSY,HIP-AIR,UV,3AL,LESS QD
10001766 RESPIRATOR ASSY,HIP-AIR,UE,3AL,FOSTER BR
10001767 COMB. PD APPARATUS,ULT. ELT., MED,BLACK
10001768 COMB. PD APPARATUS,ULT. ELT., MED,BLACK
10001769 COMB. PD APPARATUS,ULT. ELT., MED,BLACK
10001770 COMB. PD APPARATUS,ULT. ELT., MED,BLACK
10001771 COMB. PD APPARATUS,ULT. ELT., MED,BLACK
10001772 COMB. PD APPARATUS,ULT. ELT., MED,BLACK
10001773 COMB. PD APPARATUS,ULT. ELT., MED,BLACK
10002092 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002093 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002094 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002095 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002096 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002097 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002098 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002099 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002101 RESPIRATOR ASSY,COMB PD,UE FCPC,FOSTER B
10002103 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002104 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002105 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002106 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002107 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002108 COMB. PD APPA.,LFT SIDE,MED,HYCAR,BLACK
10002120 RESPIRATOR ASSY,COMB PD,UV FCPC,FOSTER B
10002121 RESPIRATOR ASSY,COMB PD,UV FCPC,FOSTER S
10002122 COMB. PD APPA.,IN CASE,LFT SIDE,MED,BLK
10002123 COMB. PD APPA.,IN CASE,LFT SIDE,MED,BLK
10002124 COMB. PD APPA.,IN CASE,LFT SIDE,MED,BLK
10002125 RESPIRATOR ASSY,COMB PD,UV FCPC,HANSEN B
10002126 COMB. PD APPA.,IN CASE,LFT SIDE,MED,BLK
10002127 RESPIRATOR ASSY,COMB PD,UV FCPC,W/O QD
10002129 COMB. PD APPA.,IN CASE,LFT SIDE,MED,BLK
10002131 COMB. PD APPA.,IN CASE,LFT SIDE,MED,BLK
10002132 COMB. PD APPA.,IN CASE,LFT SIDE,MED,BLK
10002133 COMB. PD APPA.,IN CASE,LFT SIDE,MED,BLK
10002134 RESPIRATOR ASSY,COMB PD,UE FCPC,HANSEN B
10002135 COMB. PD APPA.,IN CASE,LFT SIDE,MED,BLK
474961 APPA-HIP,COMB.PD DUF CASE
485527 APPA,PD-HIP COM CYL FOSST
485528 APPA,PD-HIP,COM CYL,HAN,B
485534 APPA,PD-HIP,COMP,FOS,W/CS
485535 APPA,PD-HIP,COMP,HAN,W/CS
Ordering Info


© MSA 2007. All Rights Reserved.